FEATURE

 

1. The gauge is suitable for detecting the super high,speeding interval and back diatance gauge 1520mm railway track.

2. With Blisters scale ,Gauge scale and super high scale , also suitable for night with LED light

3. LED lighting battery can work continuously for 100 hours at a time

4.With detection data storage function, you can upload the computer to determine the fault in the form of curve

5.Automatic correction of environmental temperature effects to reduce detection errors

 

PRODUCT PARAMETER

1.Product model and grade

 

                Model          Accuracy   Applicable railway line
     

        GJC-JG0

         Level   0  ueds for railway  speed  ≤250km/h
           GJC-JG1          Level   2 ueds for railway  speed  ≤160km/

2.Gauge range and error unit of gauge (mm)

                       Item               Measure range/mm        Allowed tolerance
                  Railwaygauge              1495~1555mm                 ±0.25
                 Extra high              -150~-150mm

———

       Guard rall check gague               1466~1486mm                   ±0.30
                Back diatance              1423~1443mm               ±0.30

 3The parallel and ultra high error of the rail surface

 

Accuracy Parallelism of  the lap rail surface Allowed tolerance for super height Allowed tolerance for height display Ultra-highturn-around erro Hype-High value repetability
Level 1 ≤0.15 ±0.20          ±0.45 ≤0.40 ≤0.15
Level 2 ≤0.20      ±0.60 ±1.20 ≤1.20 ≤0.40

Precautions

1.Handle gently to avoid collision

2.Pls turn off the power after used and put in clean and safe place